KGRKJGETMRETU895U-589TY5MIGM5JGB5SDFESFREWTGR54TY
Server : Apache/2.4.62
System : FreeBSD fbsdweb2.web.rcn.net 14.1-RELEASE FreeBSD 14.1-RELEASE releng/14.1-n267679-10e31f0946d8 GENERIC amd64
User : www ( 80)
PHP Version : 8.3.8
Disable Function : NONE
Directory :  /domains/pauljbrock/

Upload File :
current_dir [ Writeable ] document_root [ Writeable ]

 

Current File : /domains/pauljbrock/ce440.html
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN" "http://www.w3.org/TR/html4/loose.dtd">
<html>

<head>
	

<style type="text/css" title="currentStyle" media="screen">

@import "style plain.css";
	</style>

	

<title>Welcome to Exeter Analytical, Inc.</title>
</head>

<body>	

        <div id="pageContainer">

            <div id="headerContainer">

                <div id="header">
                    <div id="top_logo">
                    <a href="index.html"><img src="images/top_logo.jpg" 
                          width="600" height="64"></a>
                            <a href="http://www.eai1.com/"><img src="images/flags/canada.jpg"></A>
                            <a href="http://www.exeteranalytical.co.uk/"><img src="images/flags/United Kingdom.jpg"></A>
                            <a href="http://www.exeteranalytical.co.uk/"><img src="images/flags/European Union.jpg"></A>
                            <a href="http://www.sciglobe.net/"><img src="images/flags/japan.jpg"></A>
                            <a href="http://www.well-group.com.cn/"><img src="images/flags/china.jpg"></A>
                            <a href="http://www.nanoequipamentos.com/"><img src="images/flags/brazil.jpg"></A>
                            <a href="http://www.analiticasa.com.ar/"><img src="images/flags/argentina.jpg"></A>
                            <a href="http://www.eai1.com/"><img src="images/flags/india.jpg"></A>

                    </div>
                </div>

                <div id="headerSpacer">
                </div>
            </div>





            <div id="navContainer">
			
                <div id="navCentralColumn">
                    <div id="leftNav">
	              <ul>
                    <li><a href="index.html">HOME</a></li>
                    <li><a href="consume.html">SUPPLIES & CONSUMABLES</a></li>
                    <li><a href="contact.html">CONTACT US</a></li>
                    <li><a href="support.html">SUPPORT and APPLICATION NOTES</a></li>
                    <li><a href="reps.html">INTERNATIONAL REPRESENTATION</a></li>   </ul>
                    </div>
				
                    <div id="navBanner">
                    </div>
				
                    <div class="clearBoth">
                    </div>     
                </div>
		</div>
            <div id="headerSpacer">
            </div>






<P ALIGN=CENTER>
<FONT SIZE=5>CE440 Elemental Analyzer</FONT>
</P>

<P ALIGN=LEFT> The topics covered in our 
<A STYLE="COLOR:BLUE" HREF="video library ce440.html">Video Library </A> will answer many of your questions.
</P>


<TABLE  WIDTH = 100% BORDER=0>

	<TR VALIGN=CENTER>
		<TD WIDTH=2% ALIGN=CENTER></TD>
		<TD WIDTH=49% ALIGN=CENTER><IMG SRC="images/s_cover.jpg" ALT ="Brochure 
			Cover Image" WIDTH=158 HEIGHT=250></TD>
		<TD WIDTH=49%  ALIGN=LEFT><FONT SIZE = 3>Determining the 
		Carbon, Hydrogen, Nitrogen, Oxygen, and Sulfur content of unknowns is one of the 
		most basic and essential needs for any chemist.<BR><BR>
		You can increase productivity and maximize confidence in your CHN/O/S results with 
		the CE440 Elemental Analyzer.<BR><BR> 
		The CE440 is designed to give you accurate and reliable results, regardless of sample 
		type.<BR><BR>
		The CE440 uses thermal conductivity detection for measuring carbon, hydrogen, and 
		nitrogen, after combustion and reduction.  This time-proven technique allows 
		measurements to be made over a very wide range of concentrations.  </FONT>
		</TD>
	</TR>


	<TR>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
	</TR>

	<TR VALIGN=CENTER>
		<TD WIDTH=2% ALIGN=CENTER></TD>
		<TD WIDTH=49% ALIGN=LEFT><FONT SIZE = 3>Rapid analysis 
		for high 	productivity.  Analysis time of less than 5 minutes.<BR><BR>Low reagent 
		consumption. Industry's lowest cost per sample.</FONT>
		</TD>
		<TD WIDTH=49% ALIGN=CENTER><IMG SRC="images/consumables1.jpg" 
				 WIDTH=200 HEIGHT=150>
		</TD>
	</TR>


	<TR>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
	</TR>

	<TR VALIGN=CENTER>
		<TD WIDTH=2% ALIGN=CENTER></TD>
		<TD WIDTH=49% ALIGN=CENTER><IMG SRC="images/capsule sealer.jpg" ALT="Coal 
			Image"  WIDTH=179 HEIGHT=120></TD>
		<TD WIDTH=49%  ALIGN=LEFT><FONT SIZE = 3>
		Unique combustion technique makes possible the analysis of any sample type, from 			volatiles to refractories.<BR><BR> Horizontal sample injection removes interfering 			residue between each sample run.</FONT>
		</TD>
	</TR>

	<TR>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
	</TR>

	<TR VALIGN=CENTER>
		<TD  WIDTH=2% ALIGN=CENTER></TD>
		<TD WIDTH=49% ALIGN=LEFT><FONT SIZE = 3>
		 Windows&reg; based software with data storage for statistical analysis and flexible 			report generation.
		<BR><BR> Continuos diagnostics and automatic maintenance alerts.</FONT>
		</TD>
		<TD WIDTH=49% ALIGN=CENTER><IMG SRC="images/sample filling.jpg" ALT="Agriculture 
			Image"   WIDTH=169 HEIGHT=120></TD>
	</TR>

	
	<TR>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
	</TR>
	<TR>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
		<TD>&#160;</TD>
	</TR>

</TABLE>


<P ALIGN=CENTER>
<FONT SIZE=5>Only the CE440 offers you all these advantages</FONT>
</P>



<TABLE  WIDTH = 100%>
	<TR>
		<TD WIDTH=2% VALIGN=TOP ALIGN=LEFT></TD>
		<TD WIDTH=98% VALIGN=TOP ALIGN=LEFT><FONT SIZE = 3>
		
<BR>	
	<B>Accuracy and Precision</B> - The CE440 provides analytical data of unsurpassed 
accuracy and precision.  The complete control of combustion parameters combined with steady 
state measurement of combustion products ensures a level of accuracy and precision that cannot 
be matched.&#160;&#160;<A STYLE="COLOR:BLUE" HREF="sensit.html">Sample Data</A><BR><BR>


	<B>Versatility</B> - With its unique combination of both static and dynamic combustion, 
the CE440 can combust the widest range of sample types of any CHN/O/S instrument.  Our unique 
horizontal furnace allows for automatic removal of the residue from each sample after analysis, 
avoiding memory effects and gas flow problems, which can occur with vertical 
furnace systems.<BR><BR>

	<B>Reliability</B> - The CE440 is a fully automated CHN/O/S elemental analyzer. 
The system with its Window&reg; based P.C. operating software has been designed to reduce 
human error through incorporation of extensive automation, customer help, and diagnostic 
facilities.  Using the technique of steady-state measurement of combustion products, the 
CE440 is inherently more reliable than gas chromatographic systems which are dependent on 
flow, column temperature, and dead volume management.<BR><BR>

	<B>Low Operating Costs</B> - With the lowest operating costs of any elemental analyzer 
available, the CE440 won't strain your budget.  Low gas and reagent consumption combined with 
higher reduction tube life make it the most economical CHN/O/S elemental analyzer to operate.
<BR><BR>

	<B>Diagnostics</B> - Continuous diagnostics and automatic maintenance alerts make 
operation almost fool-proof.  By monitoring signals, voltages, and sample throughput, the 
instrument provides you with continuous status reports on consumable reagents as well as an 
immediate warning should a problem occur.  And, most parts are user-replaceable, further 
reducing cost and downtime.<BR><BR>


		</TD>
	</TR>
</TABLE>



<P ALIGN=CENTER>
<FONT SIZE=5>CE440 Features</FONT>
</P>

<TABLE  WIDTH = 100%>
	<TR>
		<TD WIDTH=2% VALIGN=TOP ALIGN=LEFT></TD>
		<TD WIDTH=98% VALIGN=TOP ALIGN=LEFT><FONT SIZE = 3>
		

	<B>Rapid analysis for high productivity</B> - analysis time of less than 5 minutes per 
sample.<BR><BR>

	<B>Unique combustion technique</B> - makes it possible to analyze any sample type, 
from volatiles to refractories.<BR><BR>

	<B>Stable thermal conductivity detectors</B> - provides linear response with superior 
precision and accuracy.<BR><BR>

	<B>Windows&reg;  software</B> - with data storage for statistical analysis and 
flexible report generation.<BR><BR>

	<B>Horizontal sample injection</B> - removes interfering residue between each 
sample run.<BR><BR>

	<B>Continuous diagnostics</B> - with automatic maintenance alerts.<BR><BR>

	<B>Low reagent consumption</B> - industry's lowest cost per sample.<BR><BR>


		</TD>
	</TR>
</TABLE>



<P ALIGN=CENTER>
<FONT SIZE=5>Applications</FONT>
</P>

<TABLE  WIDTH = 100%>
	<TR>
		<TD WIDTH=2% VALIGN=TOP ALIGN=LEFT></TD>
		<TD WIDTH=98% VALIGN=TOP ALIGN=LEFT><FONT SIZE = 3>


With its wide linear range, combined static/dynamic combustion and unique horizontal furnace design allowing for the removal of sample residue between runs, the CE440 is capable of analyzing the widest range of sample types - quickly, easily, and reliably.  Typical applications include: <BR><BR>


<B>Organics and Pharmaceuticals</B> - The CE440 can analyze virtually any class of organics, including organometallics, heterocyclic nitrogen derivatives, steroids, polynuclear aromatics, and organophosphorous. <BR><BR>


<B>Environmental</B> - Analyse the effects of fuels, oils, and their by-products on the environment, study the composition of 
material retained by membranes used in oceanography, water filtration, and air monitoring, or the composition of waste materials.<BR><BR>



<B>Polymers</B> - The CE440 provides a fast, direct method for determining elemental composition of polymers, copolymers, and blends.  Even samples with high levels of halogens, like PVC or Teflon&reg;, can be analyzed rapidly and accurately.<BR><BR>


<B>Refractories</B> - Nitrides, graphite fibers, and ceramics are easily analyzed - even carbides with melting points over 2000&deg;C.<BR><BR>


<B>Volatile/Air Sensitive Samples</B> - Volatile and air sensitive materials are easily analyzed using our capsule sealing device.<BR><BR>


<B>Other Application Areas:</B>  - Plastics, petrochemicals, agriculture, food, and pyrotechnical compounds.
<BR><BR>


		</TD>
	</TR>
</TABLE>


<P ALIGN=CENTER>
<FONT SIZE=5>Available Options</FONT>
</P>


<TABLE  WIDTH = 100%>
	<TR>
		<TD WIDTH=2% VALIGN=TOP ALIGN=LEFT></TD>
		<TD WIDTH=98% VALIGN=TOP ALIGN=LEFT><FONT SIZE = 3>

In addition to the primary 64 sample automated CE440 Model, Exeter Analytical, Inc. 
offers other Models and several accessories to customize your system for your particular requirements.
<BR><BR>

	<B>Manual Injection</B> - Lower cost, requires manual injection. Ideal for ash content 
measurement as you have the ability to withdraw and weight the sample boat after combustion.<BR><BR>

 <B>  Single Sample Automation</B> - If you only run a few samples at a time, this feature 
will let you manually introduce a sample, then it will run the analysis automatically. <BR><BR>

<B>  Capsule Sealer</B> - This device ensures sample integrity by cold welding tin 
sample capsules shut.  Analyzing highly volatile samples such as gasoline and oils becomes routine.<BR><BR>

<B>  Refractory Materials Kit</B> - This kit contains fluxes and special sleeves for the 
combustion of difficult samples requiring rigorous conditions for extracting carbon and 
nitrogen.<BR><BR>

Exeter Analytical, Inc. is a company specializing in the manufacture of elemental analyzers.  
We can provide support and advise on all application areas and we run a CHN/O/S application 
laboratory to assist you in getting the best results on your samples.

		</FONT>

		</TD>
	</TR>
</TABLE>

<BR><BR>

<A HREF="brochure.pdf"> Download Brochure (Adobe PDF Format) </A><BR><BR>

<A HREF="paper.pdf"> Download CE440 Design Document </A><BR><BR>

<A HREF="specs.pdf"> Download CE440 Specifications </A><BR><BR>

<A HREF="440info.pdf"> Download CE440 Principles of Operation Document  </A><BR><BR>








              
<! ***********************************************************************************************   break  >

            <!    <div id="footer">
                <div id="footerContent"> 
                <p>Exeter Analytical, Inc &middot; 7 Doris Drive, Unit#6A &middot; North Chelmsford, MA 01863, 
                   USA &middot; 800-440-7875
                </p>
		    <p>Exeter Analytical (UK), Ltd. &middot; University of Warwick Science Park <br />Sir William 
                   Lyons Road &middot; Coventry &middot; CV4 7EZ &middot; UK &middot; +44(0)24 76323223
                </p>
                </div>
            </div>
        </div>


</body>
</html>


Anon7 - 2021