Server : Apache/2.4.62 System : FreeBSD fbsdweb2.web.rcn.net 14.1-RELEASE FreeBSD 14.1-RELEASE releng/14.1-n267679-10e31f0946d8 GENERIC amd64 User : www ( 80) PHP Version : 8.3.8 Disable Function : NONE Directory : /domains/gpinc1/ |
Upload File : |
<!DOCTYPE HTML PUBLIC "-//IETF//DTD HTML//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
<meta name="GENERATOR" content="Microsoft FrontPage 5.0">
<title>RC4000M Reel Control</title>
</head>
<body bgcolor="#FFFFF2">
<div align="center"><center>
<table align="center" height="20%" width="100%">
<tr>
<td align="left" bgcolor="#fffff2" width="360" height="77"><a href="default.htm">
<img src="images/geweblog.jpg" alt="Gordon Engineering Corp." width="300" border="0"></a></td>
<td align="center" width="10" bgcolor="#fffff2"></td>
<td align="center" bgcolor="#fffff2"></td>
<td align="right" valign="bottom" bgcolor="#fffff2" colspan="2"><font size="6">RC4000M Reel Control</font>
<br><font size="2"><em>for direct control of Permanent Magnet and Shunt Wound DC Motors</em><br> </font></td>
</tr>
<tr>
<td align="center" height="1" colspan="3" bgcolor="#fffff2"></td>
<td align="center" height="1" colspan="2" bgcolor="#000000"></td>
</tr>
</table>
<table height="80%" width="100%" border="0">
<tr>
<td align="right" valign="center" width="40%"><font size="5">RC4000M Reel Controls</font><br>
<font size="4">Our proven non-contact sensing method provides smooth, stress-free control of
conductive materials, even fine wire and delicate stamped parts.</p>
<p><font color="#ff0000">Please Note: the system shown is comprised of the RC4000M
control unit, a cable and an antenna assembly. To accommodate the widest variety of
potential applications, in the simplest manner, these components are sold as separate
line items.</p></font></td>
<td align="center" bgcolor="#fffff2"></td>
<td width="398" align="center"><img src="images/RC4000M.jpg" alt="Image of RC4000M Reel Control" width="398" height="256"></td>
</tr>
</table>
</center></div>
<div align="center"><center>
<table background="images/bk21.gif" border="1" bordercolor="#000000" width="100%">
<tr>
<td align="center" height="10" colspan="5" bgcolor="#000000"></td>
</tr>
<tr>
<td align="center" height="40" bgcolor="#FFFFa2"><a href="4000F&B.htm"><font size="5">Features/Benefits</font></a></td>
<td align="center" rowspan="3" width="5" bgcolor="#000000"></td>
<td align="center" valign="center" bgcolor="#FFFFa2"><a href="4000Mspecs.htm"><font size="5">Specifications</font></a></td>
<td align="center" rowspan="3" width="5" bgcolor="#000000"></td>
<td align="center" bgcolor="#FFFFa2">
<!-- <a href="4000Mprice.htm"><font size="5">Prices</font></a> -->
</td>
</tr>
<tr>
<td align="center" bgcolor="#000000" height="5"></td>
<td align="center" bgcolor="#000000" height="5"></td>
<td align="center" bgcolor="#000000" height="5"></td>
</tr>
<tr>
<td align="center" height="40" bgcolor="#FFFFa2"><a href="4000apps.htm"><font size="5">
Applications</font></a></td>
<td align="center" bgcolor="#FFFFa2"><a href="4000modant.htm"><font size="5">Modular Antennas</font></a></td>
<td align="center" bgcolor="#FFFFa2"><a href="pub\RC4000%20Manual%20screen.pdf"><font size="4">RC4000M Manual</font></a><br>
<font size="2">922 Kb PDF file</font></td>
</tr>
<tr>
<td align="center" height="5" colspan="5" bgcolor="#000000"></td>
</tr>
</table>
</center></div>
<p> </p>
<hr>
<p><font color="#0080FF" size="6">Principles of Operation</font></p>
<p>The <strong>RC4000M Reel Control</strong></font>
system is comprised of: a <strong>control unit</strong>,
a <strong>cable</strong>, and an <strong><a href="4000modant.htm">antenna assembly</a></strong>.</p>
<p>The RC4000M is designed to directly control permanent magnet and shunt wound DC motors, up to
� HP / 90 volt armature or 1 HP / 180 volt armature.
</p>
<p>The control unit determines the load and status of the antenna assembly and establishes
a tuned, RF sensing field around the antenna elements (yellow, inner pieces). This field
is shaped, through the use of grounded shield elements (black, outer pieces), and is
essentially contained within the "V".</p>
<p>Once the system is properly installed and configured for your application, the operator
simply presses the <strong>TUNE</strong> button. The tuning process takes only a few seconds. Then, the
operator positions the payoff or take-up loop within the "V", either manually or with
the use of the <strong>JOG</strong> button, so that one of the green Loop Height indicators is lit.
Once these conditions are met, he/she presses the <strong>AUTO/STANDBY</strong> button and the system
is functional.</p>
<p>After your operation is running, you may find that you want to adjust the loop height,
relative to the antenna. This is as easy as pressing the <strong>ADJUST</strong> Up or Down buttons
located next to the bargraph indicators. This is done dynamically, with the motor
running. A pair of selectable relays for <strong>HIGH</strong> and <strong>LOW LIMIT</strong> are
included in the control unit. These act in a similar manner to stand alone models of limit switches, with the
exception that there is no contact with the material required by our limit relays.
The result is non-contact protection against tight or slack loop conditions.</p>
<p>If you have any questions just call our Sales Dept. at 1.800. 315. 9233
or <a href="mailto:[email protected]">e-mail</a> us,
whichever is more convenient.</p>
<p height="15"></p>
<div align="center">
<br>
<table align="left" cellspacing="5" border="2" bgcolor="#ffffc2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" height="80" width="100%">
<tr>
<td align="center" bgcolor="#fffff2" rowspan="2" width="15%"><a href="http://www.gordonproducts.com/default.htm">
<img src="images/GP_LOGO2.jpg" alt="Link to Gordon Products, Inc." border="0" WIDTH="244" HEIGHT="65"></a></td>
<td align="center" bgcolor="#000000" width="27%"><a href="productind.htm">
<font color="#ffffff" size="3">Product Directory</font></a></td>
<td align="center" bgcolor="#000000" width="18%"></td>
<td align="center" bgcolor="#000000" width="25%"><a href="RC4000M.htm">
<font color="#ffffff" size="3">Top of Page</font></a></td>
<td align="center" bgcolor="#fffff2" rowspan="2" width="15%"><a href="default.htm">
<img src="images/Ge_home.jpg" alt="GE Home Page" border="0" WIDTH="100" HEIGHT="49"></a></td>
<tr>
<td align="center" bgcolor="#000000" colspan="3">
<font color="#ffffff" size="3"><strong>� copyright 1998 - 2008 Gordon
Engineering Corp.</strong></font></td>
</tr>
</table>
</div>
<script language="JavaScript" type="text/javascript" src="webtraxs.js"></script>
<noscript><img alt="" src="http://db2.webtraxs.com/webtraxs.php?id=gordoneng&st=img"></noscript>
</body>
</html>