KGRKJGETMRETU895U-589TY5MIGM5JGB5SDFESFREWTGR54TY
Server : Apache/2.4.62
System : FreeBSD fbsdweb2.web.rcn.net 14.1-RELEASE FreeBSD 14.1-RELEASE releng/14.1-n267679-10e31f0946d8 GENERIC amd64
User : www ( 80)
PHP Version : 8.3.8
Disable Function : NONE
Directory :  /domains/gpinc1/

Upload File :
current_dir [ Writeable ] document_root [ Writeable ]

 

Current File : /domains/gpinc1/pc1000.htm
<!DOCTYPE HTML PUBLIC "-//IETF//DTD HTML//EN">
<html>

<head>
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
<meta name="GENERATOR" content="Microsoft FrontPage 5.0">
<title>PC1000 Proxagard</title>
</head>

<body bgcolor="#FFFFF2">

<div align="center"><center>

<table align="center" height="20%" width="100%">

    <tr>
        <td align="left" bgcolor="#fffff2" width="360" height="77"><a href="default.htm">
        <img src="images/geweblog.jpg" alt="Gordon Engineering Corp." border="0" width="300" height="77"></a></td>
        <td align="center" width="10" bgcolor="#fffff2"></td>
        <td align="center" valign="center" bgcolor="#fffff2"><font size="5">&nbsp;<br><br></font>
        <a href="mailto:[email protected]"><font size="4">[email protected]</font></a></td>
        <td align="right" valign="bottom" bgcolor="#fffff2" colspan="2"><font size="6" color="#000000">PC1000</font><br>
        <font size="5"> Proxagard</font><sup>�</sup><font size="5"> System</font></td>
    </tr>
    <tr>
        <td align="center" height="1" colspan="2" bgcolor="#fffff2"></td>
        <td align="center" height="1" colspan="3" bgcolor="#000000"></td>
    </tr>

</table>

<table border="0">
    <tr>
        <td colspan="3"><p>&nbsp;</p></td>
    </tr>
    <tr>
        <td align="right" valign="center"><font size="4">A
        capacitive, presence sensing device designed for machine
        guarding and personnel safety applications.</font>
        <p>Features microprocessor-based electronics, automatic tuning and
        sensitivity adjustments, continuous self-check circuitry,
        warning output, enhanced relay protection (includes
        welded contact detection) and ability to handle up to 150
        linear feet of antenna.</p>
        <p><img border="0" src="images/cuslisth.gif" width="150" height="55"></p></td>
        <td align="right" width="30"></td>
        <td width="398" align="center"><img src="images/PC1000.jpg" alt="Image of PC1000 Proxagard" width="398" height="258"></td>
    </tr>
</table>

</center></div>

<div align="center"><center>

<table background="images/bk21.gif" border="1" bordercolor="#000000" width="100%">
    <tr>
             <td align="center" height="10" colspan="5" bgcolor="#000000"></td>
    </tr>
    <tr>
        <td bgcolor="#ffffd2" align="center" height="40"><a href="pc1000specs.htm"><font size="5">Specifications</font></a></td>
        <td align="center" rowspan="3" width="5" bgcolor="#000000"></td>
        <td bgcolor="#ffffd2" align="center" valign="center" rowspan="3"><a href="1000apps.htm"><font size="5">
        Applications</font></a></td>
        <td align="center" rowspan="3" width="5" bgcolor="#000000"></td>
        <td bgcolor="#ffffd2" align="center">
<!--		<a href="pc1000prc.htm"><font size="5">Prices</font></a> -->
		&nbsp;</td>
    </tr>
    <tr>
        <td align="center" bgcolor="#000000" height="5"></td>
        <td align="center" bgcolor="#000000" height="5"></td>
    </tr>
    <tr>
        <td bgcolor="#ffffd2" align="center" height="40"><a href="pc1000ant.htm"><font size="5">Antenna Design</font></a></td>
        <td bgcolor="#ffffd2" align="center"><font size="5">
        <a href="Pipe%20Clamps.htm">Insulators</a></font></td>
    </tr>
    <tr>
             <td align="center" height="5" colspan="5" bgcolor="#000000"></td>
    </tr>
</table>

</center></div>

<p>&nbsp;</p>

<hr>

<p><font color="#0080FF" size="6">Principles of Operation</font></p>

<p>The <strong>PC1000 Proxagard</strong><font size="1"><strong>�</strong></font>
system components are: a <strong>control unit</strong>,
a <strong>coupler</strong>, and a <strong>customer-supplied
antenna</strong>. </p>

<p>The control unit interfaces electrically with the coupler, by
means of the coupler cable. The coupler is electrically and
mechanically connected to the antenna, which is constructed near
or around the area to be guarded.</p>

<p>The <strong>coupler</strong> generates an
electromagnetic field which surrounds the antenna. Any intrusion
into the field by personnel, machinery or metal parts causes a
change in the field. The <strong>control unit</strong>
detects this change and opens the control relay in the <strong>Stop
Output</strong> circuit, which can be used to remove
power, apply a brake or perform some other desired safety
function. The Stop Output also has a safety
relay, with its contacts wired in series with
those of the control relay. The safety relay works in
conjunction with an armature configuration in the control relay
that allows a welded relay contact to be detected, and opens the
Stop Output if a contact weld occurs. A separate, adjustable <strong>Warning
Output </strong>provides a means to alert personnel
to the fact that they are in the sensing field - this feature helps
to eliminate unintended machine stops.</p>

<p><strong>On initial power-up</strong>, the
<strong>Proxagard</strong><font size="1"><strong>�</strong></font>
<strong>tunes automatically</strong> with the
system sensitivity defaulted to maximum. The <strong>keypad</strong>
allows the authorized user to retune and alter the
sensitivity or warning settings; these new settings are
stored in memory and become the defaults for subsequent
power-ups. An <strong>access code</strong> prevents unauthorized keypad entry. 
The <b>keylock</b> is needed to allow the acess code to be entered.&nbsp; It 
becomes a second level of security to reduce operator adjustments to the system.
The alarm point and field activity are displayed on a bargraph,
during normal operation.</p>

<p>The <strong>self-check circuit</strong>, which
monitors the control circuitry, operates continuously and is
independent of machine cycle. In the event of a self-check
fault, the Stop Output opens and a fault code
is displayed on the bargraph.</p>

<hr>

<p align="center"><font size="4"><strong>Meets 
<a href="http://www.osha-slc.gov/OshStd_data/1910_0217.html">OSHA
Standard 1910.217</a> (c) (3) (iii)</strong></font></p>

<div align="center"><center>

<table border="0" width="100%">
    <tr>
        <td><font size="4"><img src="images/RedBall.gif" width="25" height="13">Machine
        Guarding </font></td>
        <td align="center"><font size="4"><img src="images/RedBall.gif" width="25" height="13">Safety Interlock
        </font></td>
        <td align="right"><font size="4"><img src="images/RedBall.gif" width="25" height="13">Machine
        Stop </font></td>
    </tr>
    <tr>
        <td>&nbsp;</td>
    </tr>
    <tr>
        <td align="right"><font size="4"><img src="images/RedBall.gif" width="25" height="13">Parts
        Detector</font></td>
        <td>&nbsp;</td>
        <td align="left"><font size="4"><img src="images/RedBall.gif" width="25" height="13">Warning Alarm</font></td>
    </tr>

</table>

<hr>

<p align="left"><font size="4"><img src="images/BlueBall.gif" width="25" height="13">Easily
Installed by Plant Electrician</font></p>

<p align="left"><font size="4"><img src="images/BlueBall.gif" width="25" height="13">Complete
Access and Visibility at Point of Operation</font></p>

<p align="left"><font size="4"><img src="images/BlueBall.gif" width="25" height="13">Antennas are
Application-Specific and can be Any Shape or Configuration</font></p>

<p align="left"><font size="4"><img src="images/BlueBall.gif" width="25" height="13">Antennas Can Be
Metal Rod, Pipe, Tubing or Flat Stock, Mounted on Insulators</font></p>

<p align="left"><font size="4"><img src="images/BlueBall.gif" width="25" height="13">Cost-Effective
Guarding Solution for Complex Machines or Irregularly Shaped
Areas</font></p>

</center></div>

<hr>

<hr>

<div align="center"><center>

<table align="left" cellspacing="5" border="2" bgcolor="#ffffc2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" height="80" width="100%">

    <tr>
        <td align="center" bgcolor="#fffff2" rowspan="2" width="15%"><a href="http://www.gordonproducts.com/default.htm">
        <img src="images/GP_LOGO2.jpg" alt="Link to Gordon Products, Inc." border="0" width="244" height="65"></a></td>
        <td align="center" bgcolor="#000000" width="27%"><a href="productind.htm">
        <font color="#ffffff" size="3">Product Directory</font></a></td>
        <td align="center" bgcolor="#000000" width="18%"></td>
        <td align="center" bgcolor="#000000" width="25%"><a href="pc1000.htm">
        <font color="#ffffff" size="3">Top of Page</font></a></td>
        <td align="center" bgcolor="#fffff2" rowspan="2" width="15%"><a href="default.htm">
        <img src="images/Ge_home.jpg" alt="GE Home Page" border="0" width="100" height="49"></a></td>
    <tr>
        <td align="center" bgcolor="#000000" colspan="3"><font color="#ffffff" size="3">
        <strong>� copyright 1998 - 2008 Gordon Engineering Corp.</strong></font></td>
    </tr>

</table>

</center></div>
<!--AAI div. Marketing Assistance, Inc. SNIPPET//-->
<script type="text/javascript">
//<![CDATA[
var DID=171960;
var pcheck=(window.location.protocol == "https:") ? "https://stats.sa-as.com/live.js":"http://stats.sa-as.com/live.js";
document.writeln('<scr'+'ipt async src="'+pcheck+'" type="text\/javascript"><\/scr'+'ipt>');
//]]>
</script>
<!--AAI div. Marketing Assistance, Inc. SNIPPET//-->

<script language="JavaScript" type="text/javascript" src="webtraxs.js"></script>
<noscript><img alt="" src="http://db2.webtraxs.com/webtraxs.php?id=gordoneng&st=img"></noscript>
</body>
</html>

Anon7 - 2021