|
Server : Apache/2.4.62 System : FreeBSD fbsdweb2.web.rcn.net 14.1-RELEASE FreeBSD 14.1-RELEASE releng/14.1-n267679-10e31f0946d8 GENERIC amd64 User : www ( 80) PHP Version : 8.3.8 Disable Function : NONE Directory : /domains/gpinc/ |
Upload File : |
<!DOCTYPE HTML PUBLIC "-//IETF//DTD HTML//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
<title>Specifications for 12A907 - Triaxial Bulkhead Connector </title>
</head>
<body bgcolor="#9f9fcf">
<div align="left">
<table align="left" cellspacing="5" background="images/bk21.gif" border="2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" height="100%" width="20%">
<tr>
<td align="center" height="10%" background="images/gp%20tartan.gif"><a href="12A907.htm">
<img src="images/12A907.gif" alt="Back to 12A907" border="0" width="120" height="40"></a></td>
</tr>
<tr>
<td background="images/gp%20tartan.gif" height="10%" align="center" valign="center"><a href="12A907_specs.htm#specs">
<img src="images/specs.gif" alt="12A907 Electrical Specifications" border="0" width="120" height="40"></a></td>
</tr>
<tr>
<td background="images/gp%20tartan.gif" height="10%" align="center" valign="center"><a href="12A907_specs.htm#install">
<img src="images/setup.gif" alt="Installation/Setup" border="0" width="120" height="40"></a></td>
</tr>
<tr>
<td background="images/gp%20tartan.gif" height="10%" align="center" valign="center"><a href="lifetime.htm">
<img src="images/warranty.gif" alt="Warranty" border="0" width="120" height="40"></a></td>
</tr>
<tr>
<td background="images/gp%20tartan.gif" height="10%" align="center" valign="center"><a href="contact.htm">
<img src="images/contact.gif" alt="Contact Us" border="0" width="120" height="40"></a></td>
</tr>
<tr>
<td background="images/gp%20tartan.gif" height="10%" align="center" valign="center"><a href="links.htm">
<img src="images/links.gif" alt="Links" border="0" width="120" height="40"></a></td>
</tr>
<tr>
<td align="center" height="40%" bgcolor="#ffffd2"><a href="default.htm">
<img src="images/GP_bord_home.jpg" alt="Home Page" border="0" WIDTH="94" HEIGHT="120"></a></td>
</tr>
</table>
</div>
<table align="center" cellspacing="5" background="images/bk21.gif" border="2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" height="12%" width="78%">
<tr>
<td background="images/gp%20tartan.gif" align="center"><font color="#efef00" size="5">
Mechanical Specifications and Wiring</font></td>
</tr>
</table>
</div>
<div align="center">
<table cellspacing="5" cellpadding="5" background="images/bk21.gif" border="2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" height="88%" width="78%"><a name="wire"></a>
<tr>
<td align="center" valign="center" bgcolor="#ffffd2"><img src="images/12A907_dim.gif" height="130" width="390" alt="12A907 Dimensions" border="0"></td>
<td align="center" valign="center" bgcolor="#ffffd2"><img src="images/12A907_wir.gif" height="130" width="130" alt="12A907 Wiring Diagram" border="0"></td>
</tr>
<tr>
<td align="left" valign="center" bgcolor="#ffffd2"><font size="2"><strong>Housing: </strong>
brass, bright nickel-plated; patented, heat-treated, beryllium-copper outer conductor spring; heat-treated,
beryllium-copper center socket (gold plated)<br>
All dielectrics are machined Teflon<sup>TM</sup><br>
<br>
<strong>Ratings: </strong> MIL-C-49142, 48-hour salt spray requirement<br>
<br>
<strong>Cable for Mating Connector: </strong> Trompeter Electronics<sup>�</sup> TRC-50-1<br>
<strong>Cable Sheath: </strong> PVC (yellow)<br>
<strong>Bend Radius (minimum): </strong> .75" (19.1 mm)<br>
<br>
This data is from the Trompeter Electronics<sup>�</sup> T18A Catalog</font></td>
<td align="center" valign="center" bgcolor="#ffffd2"><img src="images/drvnshld.gif" height="182" width="130" alt="Driven Shield Sensing Element" border="0"></td>
</tr>
<tr>
<td align="center" valign="center" bgcolor="#000000"><font size="3" color="#ffffff"><strong>Mechanical Specifications</strong></font></td>
<td align="center" valign="center" bgcolor="#000000"><font size="3" color="#ffffff"><strong>Wiring Diagram</strong></font></td>
</tr>
</table>
</div>
<div align="left">
<br><a name="specs"></a>
<br>
<table cellspacing="5" cellpadding="5" background="images/bk21.gif" border="2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" width="99%">
<tr>
<td align="center" background="images/gp%20tartan.gif" height="40" colspan="6"><font color="#efef00" size="5">
Electrical Specifications for TRC-50-1 Triaxial Cable</font></td>
</tr>
<tr>
<td align="center" valign="center" bgcolor="#ffff92"><font size="3"><strong>Impedance</strong></font><br><font size="2">Ohms</font></td>
<td align="center" valign="center" bgcolor="#ffff92"><font size="3"><strong> </strong></font></td>
<td align="center" valign="center" bgcolor="#ffff92"><font size="3"><strong>Operating Voltage</strong></font><br><font size="2">maximum VDC</font></td>
<td align="center" valign="center" bgcolor="#ffff92"><font size="3"><strong>Operating Voltage</strong></font><br><font size="2">maximum VAC</font></td>
<td align="center" valign="center" bgcolor="#ffff92"><font size="3"><strong>Capacitance</strong></font><br><font size="2">pF/ft. maximum</font></td>
<td align="center" valign="center" bgcolor="#ffff92"><font size="3"><strong>Shield Coverage</strong></font></td>
</tr>
<tr>
<td align="center" valign="center" bgcolor="#000000" height="7" colspan="6"></td>
</tr>
<tr>
<td align="center" valign="center" bgcolor="#ffffd2"><font size="2"><strong>50 +/- 2</strong></font></td>
<td align="center" valign="center" bgcolor="#ffff92"><font size="2"><strong> </strong></font></td>
<td align="center" valign="center" bgcolor="#ffffd2"><font size="2"><strong>2.0 KV</strong></font></td>
<td align="center" valign="center" bgcolor="#ffffd2"><font size="2"><strong>1.0 KV</strong></font></td>
<td align="center" valign="center" bgcolor="#ffffd2"><font size="2"><strong>29. 5</strong></font></td>
<td align="center" valign="center" bgcolor="#ffffd2"><font size="2"><strong>93%</strong></font></td>
</tr>
<tr>
<td align="center" background="images/gp%20tartan.gif" height="50" colspan="6"></td>
</tr>
</table>
<br><a name="install"></a>
<br>
<table cellspacing="5" cellpadding="5" background="images/bk21.gif" border="2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" height="50%" width="99%">
<tr>
<td align="center" background="images/gp%20tartan.gif" height="10%" colspan="3"><font color="#efef00" size="5">Installation/Setup Procedures</font></td>
</tr>
<tr>
<td align="center" valign="center" bgcolor="#000000" width="50%"><font size="3" color="#ffffff"><strong>Mechanical Installation</strong></font></td>
<td align="center" valign="center" width="1"></td>
<td align="center" valign="center" bgcolor="#000000" width="49%"><font size="3" color="#ffffff"><strong>Electrical Installation</strong></font></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#ffffd2"><font size="3"><strong>
Use the mounting nut and lock washer to mount the bulkhead connector to the
grounded shield of your remote sensor.
<br>
<br> The <a href="12A907_specs.htm#wire">hole specifications</a> and mounting bracket
thickness are indicated above.<br>
<br></strong></font></td>
<td align="center" valign="center" width="1"></td>
<td align="left" valign="top" bgcolor="#ffffd2"><font size="3"><strong>
Connect the center conductor to the sensing element, the inner shield to the
driven shield element and the ground lug to the grounded shield element.<br>
<br>Please, refer to the <a href="12A907_specs.htm#wire">wiring diagram</a> above.</strong></font></td>
</tr>
<tr>
<td align="center" background="images/gp%20tartan.gif" height="20" colspan="3"> </td>
</tr>
</table>
<br>
<br>
<table align="left" cellspacing="5" background="images/bk21.gif" border="2" bordercolorlight="#d0e0e7" bordercolordark="#2626a6" height="80" width="99%">
<tr>
<td align="center" bgcolor="#ffffd2" rowspan="2" width="20%"><a href="12A907_specs.htm">
<img src="images/GP_Top.jpg" alt="Top of Page" border="0" WIDTH="72" HEIGHT="72"></a></td>
<td align="center" bgcolor="#ffffd2" width="20%"><font size="2"><em>phone: </em><br><strong>+1 800. 315. 9233</strong></font></td>
<td align="center" bgcolor="#ffffd2" width="30%"><font size="2"><em>email: </em><br></font>
<a href="mailto:[email protected]"><strong>[email protected]</strong></a></td>
<td align="center" bgcolor="#ffffd2" width="20%"><font size="2"><em>fax: </em><br><strong>+1 203. 775. 1162</strong></font></td>
<td align="center" bgcolor="#ffffd2" rowspan="2" width="10%"><a href="default.htm">
<img src="images/GP_home.jpg" alt="Home Page" border="0" width="72" height="72"></a></td>
<tr>
<td align="center" background="images/gp%20tartan.gif" colspan="3">
<font color="#efef00" size="3"><strong>� copyright 2008 Gordon Products
Incorporated</strong></font></td>
</tr>
</table>
</div>
</body>
</html>