<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html><head><title>Delta Electronics, Inc. Model RCCR-1 X 4</title></head>
<body style="background-color: white;">
<br>
<center>
<div style="text-align: center;">
<div style="text-align: center;"><img style="width: 598px; height: 102px;" alt="" src="../deltalogo.jpg"></div>
</div>
<h2 style="font-weight: bold;"><big>Model RCCR-1 X 4
Remote Controlled<br>
Coaxial Relay</big></h2>
<br>
<img style="width: 651px; height: 178px;" alt="" src="rccrobl.jpg"><br>
<br>
<br>
</center>
<hr style="height: 4px;">
<h3 style="text-align: justify;">General&nbsp;Description
of the Model RCCR-1 X 4<span style="font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;"><span style="">&nbsp;</span></span></h3>
<span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">&nbsp;
&nbsp; &nbsp;The
Model </span><span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;;">RCCR-1
X 4 Remote Controlled Coaxial Relay<span style="letter-spacing: -0.1pt;"> provides locally and
remotely controlled RF
switching between one transmitter rated at up to 2 kW average power/6
kW peak
power and four antennas operating over a DC to 32 MHz frequency range.
The
RCCR-1 X 4 provides four momentary pushbutton switches to locally
select the antenna
to be connected to the transmitter. The pushbutton switch associated
with the
selected antenna illuminates to indicate the connection of the antenna
to the
transmitter. The RCCR-1 X 4 unkeys the transmitter via the interlock
circuit
prior to RF switching to prevent hot RF switching. Upon completion and
verification of the RF switching, the RCCR-1 X 4 closes an interlock
relay to
enable the transmitter to be keyed. The RCCR-1 X 4 is equipped with a
RS-232 or
RS-422 serial data interface to enable remotely controlled RF
switching. The
RCCR-1 X 4 will implement correctly formatted connect messages and will
respond
to status requests with a message detailing the antenna connected to
the
transmitter, interlock status, local/remote mode and fault status.</span></span><br>
<br>
<span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">&nbsp;
&nbsp; &nbsp;The
modular design of
the Remote Controlled Coaxial Relay accommodates different
transmitter/antenna
switching requirements ranging from 1 transmitter/2 antennas to 1
transmitter/8 antennas as well as 2 transmitters/2 antennas transfer
switching.
Different RF power levels and operational frequency ranges varying from
2 kW
average at 32 MHz/500 W average at 400 MHz to 750 W average at 32
MHz/200 W
average at 400 MHz are accommodated by equipping the unit with
alternate
coaxial relay types or connectors. The microprocessor logic used in the
RCCR-1&nbsp;X&nbsp;4 facilitates adaptation of the program to
meet special
customer requirements such as custom serial interface formats or
descriptive
labels for the transmitter and the antennas.</span><br>
<br>
<br>
<div style="text-align: center;"><img style="width: 698px; height: 126px;" alt="" src="rccrfront.jpg"><br>
</div>
<br>
<big><span style="font-weight: bold;">Serial Data
Interface<br>
<br>
</span></big> <span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">&nbsp; &nbsp; &nbsp;The
standard serial interface is per RS-232 or RS-422 using ASCII
characters for
control and status information. The serial data format is compatible
with
computer programs developed for the Delta <a href="mcu8data.htm" target="_self">Model MCU-8C Matrix Control Unit</a>,
<a href="mcu9data.htm" target="_self">Model
MCU-9C Matrix Control Unit</a>, <a href="mssidata.htm" target="_self">Model MSSI Medium Switch Serial Interface</a>
or <a href="lssidata.htm" target="_self">Model
LSSI Large Switch Serial Interface</a> applications. Consult
factory for
optional
serial data formats or interfaces.<span style="font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">&nbsp;</span><br>
<br>
<span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">&nbsp; &nbsp; &nbsp;The
standard
serial interface characteristics are 7 data bits per character, one
start bit,
programmable one or two stop bits and programmable even or odd parity.
The baud
rate is switch selectable with standard data rates from 50 to 19,200.
The
serial input circuit provides a high input impedance and the serial
output
circuit is programmable for either active or tristate to enable serial
data bus
communication circuits.</span><br>
<hr style="height: 2px;"><br>
<table style="text-align: left; width: 567px; height: 347px;" cellpadding="7">
<tbody>
<tr>
<td style="height: 41px;" colspan="2" rowspan="1" align="undefined" valign="undefined">
<h3 style="text-align: left;">Control and Status
Word Formats</h3>
</td>
</tr>
<tr>
<td style="vertical-align: top; font-weight: bold;">A.</td>
<td style="vertical-align: top;">&nbsp;
&nbsp; &nbsp;Connect Command (Remote
Control System to RCCR-1 X 4):<br>
&nbsp; &nbsp; &nbsp;CR LF ADRS C T1 T2 A1 A2 X<br>
</td>
</tr>
<tr>
<td style="vertical-align: top; font-weight: bold;">B.</td>
<td style="vertical-align: top;"> &nbsp;
&nbsp; &nbsp;Status Command (Remote
Control System to RCCR-1 X 4):<br>
&nbsp; &nbsp; &nbsp;CR LF ADRS S T1 T2&nbsp;X<br>
</td>
</tr>
<tr>
<td style="vertical-align: top; font-weight: bold;">C.</td>
<td style="vertical-align: top;">&nbsp;
&nbsp; &nbsp;Status Response (RCCR-1 X 4&nbsp;to Remote
Control System):<br>
&nbsp; &nbsp; &nbsp;CR LF ADRS S T1 T2 A1 A2 F M I PS ETB<br>
</td>
</tr>
<tr>
<td style="vertical-align: top; font-weight: bold;">D.</td>
<td style="vertical-align: top;">&nbsp;
&nbsp; &nbsp;Complete Status&nbsp;Command (Remote Control
System to RCCR-1 X 4):<br>
&nbsp; &nbsp; &nbsp;CR LF ADRS S A L L X<br>
</td>
</tr>
<tr>
<td style="vertical-align: top; font-weight: bold;">E.</td>
<td style="vertical-align: top;">&nbsp;
&nbsp; &nbsp;Complete Status Response (RCCR-1 X 4 to remote
Control System):<br>
&nbsp; &nbsp; &nbsp;CR LF ADRS S T1 T2 A1 A2 I F M PS ETB</td>
</tr>
</tbody>
</table>
<br>
<table style="text-align: left; width: 565px; height: 860px;" cellpadding="7">
<tbody>
<tr>
<td style="height: 41px;" colspan="3" rowspan="1">
<h3 style="text-align: left;">The characters are
defined as follows:</h3>
</td>
</tr>
<tr>
<td style="height: 23px; font-weight: bold; vertical-align: middle;">CR</td>
<td style="height: 23px; text-align: right;">&nbsp;
&nbsp;= </td>
<td style="height: 23px;">&nbsp;&nbsp;&nbsp;
ASCII Carriage Return<br>
</td>
</tr>
<tr>
<td style="height: 41px; font-weight: bold;" align="undefined" valign="undefined">LF</td>
<td style="height: 41px; text-align: right;">&nbsp;
&nbsp; =</td>
<td style="height: 41px;">&nbsp; &nbsp;
ASCII Line Feed</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top;">ADRS</td>
<td style="text-align: right; vertical-align: top;">=</td>
<td style="vertical-align: top;"> &nbsp;
&nbsp; Coaxial Switch Control Panel
Address (Switch Selectable); <br>
&nbsp; &nbsp; ASCII characters 0 - 9 and A - F (Factory set to
ASCII 1)&nbsp;</td>
</tr>
<tr>
<td style="vertical-align: middle; font-weight: bold;">C</td>
<td style="text-align: right;">=</td>
<td> &nbsp; &nbsp; Command Designator for Connect
Message</td>
</tr>
<tr>
<td style="vertical-align: middle; font-weight: bold;">S</td>
<td style="text-align: right;">=</td>
<td align="undefined" valign="undefined">&nbsp;
&nbsp;&nbsp;Command Designator for Status&nbsp;Message
&nbsp;</td>
</tr>
<tr>
<td style="vertical-align: middle; font-weight: bold;">ALL</td>
<td style="text-align: right;">=</td>
<td align="undefined" valign="undefined">
&nbsp; &nbsp;&nbsp;ASCII Character String Meaning ALL
Transmitters</td>
</tr>
<tr>
<td style="font-weight: bold;" align="undefined" valign="undefined">T1</td>
<td style="text-align: right;">=</td>
<td align="undefined" valign="undefined">&nbsp;
&nbsp; Most Significant Digit of Transmitter Number (always 0)</td>
</tr>
<tr>
<td style="font-weight: bold;" align="undefined" valign="undefined">T2</td>
<td style="text-align: right;">=</td>
<td align="undefined" valign="undefined">&nbsp;
&nbsp; Least&nbsp;Significant Digit of Transmitter Number
(always 1)</td>
</tr>
<tr>
<td style="font-weight: bold;" align="undefined" valign="undefined">A1</td>
<td style="text-align: right;">=</td>
<td>&nbsp; &nbsp;&nbsp;Most Significant Digit
of Antenna&nbsp;Number (always 0)</td>
</tr>
<tr>
<td style="font-weight: bold;" align="undefined" valign="undefined">A2</td>
<td style="text-align: right;">=</td>
<td align="undefined" valign="undefined">&nbsp;
&nbsp; Least&nbsp;Significant Digit of Antenna&nbsp;Number</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top;">F</td>
<td style="text-align: right; vertical-align: top;">=</td>
<td style="vertical-align: top;">&nbsp;
&nbsp; Fault Digit<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0 = Fault<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 1 = Summary Fault<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3 = Connection
Fault</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top;">M</td>
<td style="text-align: right; vertical-align: top;">=</td>
<td style="vertical-align: top;">&nbsp;
&nbsp;&nbsp;Mode Digit<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0 = Local Mode<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 1 = Remote Mode</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top;">I</td>
<td style="text-align: right; vertical-align: top;">=</td>
<td style="vertical-align: top;">&nbsp;
&nbsp;&nbsp;Transmitter Interlock Status&nbsp;Digit<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0 = Open
Interlock<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 1 = Valid
Interlock</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top;">PS</td>
<td style="text-align: right; vertical-align: top;">=</td>
<td style="vertical-align: top;">&nbsp;
&nbsp;&nbsp;Coaxial Transfer Switch Power Supply
Status&nbsp;Digit<br>
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Always
1&nbsp;= Supply Normal</td>
</tr>
<tr>
<td style="font-weight: bold;" align="undefined" valign="undefined">X</td>
<td style="text-align: right;">=</td>
<td>&nbsp;
&nbsp;&nbsp;ASCII X to End Command Message</td>
</tr>
<tr>
<td style="font-weight: bold;" align="undefined" valign="undefined">ETB</td>
<td style="text-align: right;">=</td>
<td>&nbsp;
&nbsp;&nbsp;ASCII End of Transmission Block to End Status
Response</td>
</tr>
</tbody>
</table>
<o:p></o:p><span style="font-size: 11pt; font-family: &quot;Dutch 801 Roman&quot;;"></span>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
<br>
<hr style="height: 2px;"><br>
<div style="text-align: center;"><img style="width: 693px; height: 138px;" alt="" src="rccrrear.jpg"><br>
</div>
<br>
<hr style="height: 2px;"><br>
<h3 style="text-align: center;">SPECIFICATIONS</h3>
<div style="text-align: center;"><big><strong>Typical
Specifications for 2 kW Average High Power/32 MHz High Frequency Model
RCCR-1 X 4</strong></big><br>
</div>
<br>
<table style="text-align: left; width: 748px; height: 1069px;" cellpadding="2">
<tbody>
<tr>
<td style="font-weight: bold; width: 288px; height: 40px;" align="undefined" valign="undefined"><big><small>Model
and&nbsp;Name:</small></big></td>
<td style="width: 398px; height: 40px;" align="undefined" valign="undefined">Model RCCR-1 X 4
Remote
Controlled Coaxial Relay</td>
</tr>
<tr>
<td style="font-weight: bold; width: 288px; height: 40px;" align="undefined" valign="undefined">RF
Switching&nbsp;Configuration:</td>
<td style="width: 398px; height: 40px;" align="undefined" valign="undefined">1 Transmitter X
4 Antennas</td>
</tr>
<tr>
<td style="font-weight: bold; width: 288px; height: 40px;" align="undefined" valign="undefined">Characteristic
Impedance<big><small>:</small></big></td>
<td style="width: 398px; height: 40px;" align="undefined" valign="undefined">50 Ohms</td>
</tr>
<tr>
<td style="font-weight: bold; width: 288px; height: 40px;">Frequency
Range:
</td>
<td style="white-space: nowrap; width: 398px; height: 40px;">DC
to 32 MHz</td>
</tr>
<tr>
<td style="font-weight: bold; width: 288px; height: 45px;" align="undefined" valign="undefined">Insertion&nbsp;VSWR:</td>
<td style="width: 398px; height: 45px;">1.05 Maximum</td>
</tr>
<tr>
<td style="font-weight: bold; width: 288px; height: 50px;" align="undefined" valign="undefined">Insertion
Loss:</td>
<td style="width: 398px; height: 50px;" align="undefined" valign="undefined">0.1 dB Maximum</td>
</tr>
<tr>
<td style="font-weight: bold; width: 288px; vertical-align: top; height: 55px;">Power
Rating
with Unity VSWR:<br>
(5000 Ft Maximum Altitude)</td>
<td style="width: 398px; vertical-align: top; height: 55px;">2
kW
Average/6 kW Peak</td>
</tr>
<tr>
<td style="font-weight: bold; height: 43px;" align="undefined" valign="undefined">Cross
Channel Isolation:</td>
<td style="height: 43px;" align="undefined" valign="undefined">90 dB Minimum</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top; height: 55px;">Switching&nbsp;Speed:</td>
<td style="vertical-align: top; height: 55px;">Less
than 250
msec after operating a Path Select pushbutton switch or receiving a
valid connect command</td>
</tr>
<tr>
<td style="font-weight: bold; height: 48px;" align="undefined" valign="undefined">RF Connectors:</td>
<td style="height: 48px;" align="undefined" valign="undefined">Type N Receptacles for Transmitter
and Antennas</td>
</tr>
<tr>
<td style="height: 44px; font-weight: bold;">RF
Relay Contact
Life:</td>
<td style="height: 44px;">&gt;1
X 10<span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;"><sup>6</sup></span>
operations</td>
</tr>
<tr>
<td style="font-weight: bold; height: 63px; vertical-align: top;">Control:</td>
<td style="height: 63px; vertical-align: top;">Local:
Pushbutton Path Selection<br>
Remote: RS-232 or RS-422 Serial Data Interface</td>
</tr>
<tr>
<td style="font-weight: bold; height: 63px; vertical-align: top;">Local
Status Display:</td>
<td style="height: 63px; vertical-align: top;">Illuminated
pushbutton indicates
transmitter/antenna RF connectivity
and illuminated LED indicates transmitter interlock status</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top; height: 55px;">Serial
Data Interface:</td>
<td style="vertical-align: top; height: 55px;">RS-232
or
RS-422, baud rate selectable in standard increments from 50 through
19200 baud.</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top; height: 56px;">Error
Detection:</td>
<td style="vertical-align: top; height: 56px;">Parity,
framing and overrun error
detection
prevents faulty operation of coaxial relay</td>
</tr>
<tr>
<td style="font-weight: bold; height: 46px;">Remote
Control
Connector:</td>
<td style="height: 46px;">25 Pin "D" Connector,
DB-25P</td>
</tr>
<tr>
<td style="height: 54px;"><span style="font-weight: bold;">Interlock
Relay Contact
Rating:</span></td>
<td style="height: 54px;">90 VA</td>
</tr>
<tr>
<td style="font-weight: bold; vertical-align: top; height: 58px;">Dimensions
and Weight:</td>
<td style="vertical-align: top; height: 58px;">3.5"
(89 mm)
high by 19" (483 mm) wide by 12" (305 mm) deep, 10 pounds (4.5 kg)</td>
</tr>
<tr>
<td style="height: 63px; font-weight: bold; vertical-align: top;">Power
Requirements:</td>
<td style="height: 63px; vertical-align: top;">120
VAC, 50/60 Hz @ 0.5 Amps<br>
240 VAC, 50/60 Hz @ 0.25 Amps</td>
</tr>
<tr>
<td style="height: 63px; vertical-align: top;"><span style="font-weight: bold;">Temperature:
</span>&nbsp;</td>
<td style="height: 63px; vertical-align: top;"><span style="font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">Operating:
&nbsp;0</span><span style="font-family: Symbol; letter-spacing: -0.1pt;"><span style="">�</span></span><span style="font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">C
to +40</span><span style="font-family: Symbol; letter-spacing: -0.1pt;"><span style="">�</span></span><span style="font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">C<o:p></o:p></span><br>
<span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;"><span style=""></span></span>Storage:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;-30�C
to +71�C</td>
</tr>
</tbody>
</table></span><span style="font-size: 11pt; font-family: &quot;Times New Roman&quot;; letter-spacing: -0.1pt;">
<ul>
</ul>
<center>
<hr><br>
For additional information on any of our products, please contact <a href="mailto:[email protected]">Sales</a> to
discuss your particular requirements:
<center>
<table cellpadding="20">
<tbody>
<tr>
<td><strong>Delta Electronics, Inc.<br>
5730 General Washington Drive<br>
P. O. Box 11268<br>
Alexandria, VA 22312<br>
<br>
</strong></td>
<td><strong>Phone: (703) 354-3350<br>
U.S. Toll Free: 1-800-8-DELTA-8 (1-800-833-5828)<br>
Fax: (703) 354-0216<br>
<address>www.deltaelectronics.com</address>
Email: <a href="mailto:[email protected]">[email protected]</a></strong></td>
</tr>
</tbody>
</table>
</center>
<hr>
<center>
<table bgcolor="White" border="2" cellpadding="10">
<tbody>
<tr>
<td><strong><a href="../index.html">HOME</a></strong></td>
<td><strong><a href="../amprod.htm">AM/FM/TV
Products</a></strong></td>
<td><strong><a href="../hfprod.htm">HF/VHF/UHF
Products</a></strong></td>
</tr>
</tbody>
</table>
<font size="1">The Delta Electronics logo is a registered
trademark of Delta Electronics, Inc.</font></center>
</center>
</span>
<IMG SRC="http://cgibin.erols.com/cgi-bin/Count.cgi?df=rccr1x4.cnt&ft=0&tr=Y&dd=B&md=5&sh=F" align=absmiddle>
</body></html>