<html><head><title>Delta Electronics, Inc. 1-5/8" Coaxial Transfer Switches</title></head>
<body bgcolor="#70A0E0">
<center>
<img src=../delta1.jpg alt="Delta Electronics, Inc.">
<h2>Model 6730E and Model 6732E<br> 1-5/8" EIA Coaxial Transfer Switches </h2>
<img src="6730.jpg" alt="Model 6730E" >
</center>
<hr>
<h3>Introduction</h3>
The Model 6730E and Model 6732E Coaxial Transfer Switches are double-pole, double throw, high power switches for use with 1-5/8 inch 50 Ohm transmission line. The manually or remotely operated transfer switches enable the changing of coaxial connections between transmitters and antennas/dummy loads with a minimum of changeover or off-air-time. Transmission line switching occurs in approximately one second. The Model 6730E operates with 120 VAC, 50/60 Hz main power and the Model 6732E operates with 220/240 VAC, 50/60 Hz main power.
<h3>Description</h3>
Coaxial transfer switches are used to switch transmitters, transmission lines, antennas, dummy loads and auxiliary equipment quickly and efficiently when failures occur, when operating procedures are changed, or during scheduled maintenance periods. They also simplify equipment tuning, testing, and emergency repairs by facilitating quick checks under actual operating conditions.
<p>
Many switching requirements in a station are greatly reduced by the use of transfer switches. In complex systems, only one-third or one-fourth as many transfer switches are needed to accomplish the same switching function as a system using SPDT or SP3T type switches. If only three of the terminals in the Model 6730E or 6732E switch are employed, the switch can be used as a SPDT type.
<p>
The Coaxial Transfer Switch provides two isolated interlock circuits for each switch connection that duplicate the RF path exactly. All interlock switches open before the RF contacts open, and close after the RF contacts close to prevent switching with RF power applied. Additional internal switch contacts enable remote control and status indication. All interlock, indicator and control circuits interface the transfer switch through a connector.
<p>
The transfer switch can be remotely controlled using either a high level, direct AC main power switching interface or a low level, open collector/contact closure interface. The Model 33630A Coaxial Switch Control Panel controls either a Model 6730E or Model 6732E Coaxial Transfer Switch and indicates the switch connections. The control panel operates with 120 VAC or 220/240 VAC, 50/60 Hz main power and mounts in a standard equipment rack space of 3-1/2" high by 19" wide.
<p><center><table>
<tr><td align="middle"><img src="33630a.jpg" alt="Model 33630A"></td></tr>
<tr><td align="middle"><strong>Model 33630A Coaxial Switch Control Panel</strong></td></tr>
</table></center><p>
Optionally, the transfer switch can be supplied with internal relays to provide an open collector or contact closure interface for low level control applications. The low level control signal needs to be maintained only for the duration of the switching cycle. Low level interface relays for operation with either 12, 24 or 48 VDC control circuits are available. Consult the factory with your requirements.
<p>
<table>
<tr><td>The transfer switch may be optionally equipped with 7/8 inch EIA connectors in place of the standard 1-5/8 inch EIA connectors on any or all four ports. This option enables the switch to directly interface 50 Ohm transmission lines terminated with 7/8 inch EIA flanges without requiring the use of line reducing connectors.</td><td>
<img src="6730-875.jpg" alt="Model 6730-875"></td></tr>
</table>
<p><hr><center>
<table valign=top cellpadding=8 border bgcolor=White>
<caption><strong>SPECIFICATIONS</strong></caption>
<tr><td><table cellpadding=4 cellspacing=0>
<tr><td width=35%><strong>MODEL NUMBER</strong></td><td width=15%><strong>6730E</strong></td><td width=15%><strong>6730E1</strong></td><td width=15%><strong>6732E</strong></td><td width=15%><strong>6732E1</strong></td><tr>
<tr><td colspan=5><hr></td></tr>
<tr><td><strong>Termination, Male EIA Flange:</strong></td></tr>
<tr><td width=35%> Standard<br> Optional</td><td width=100>1-5/8 in<br>7/8 in</td><td width=100>1-5/8 in<br>7/8 in</td><td width=100>1-5/8 in<br>7/8 in</td><td width=100>1-5/8 in<br>7/8 in</td></tr>
<tr><td><strong>Frequency Range, MHz:</strong></td><td>0-400</td><td>0-900</td><td>0-400</td><td>0-900</td></tr>
<tr><td><strong>Impedance, Ohms:</strong></td><td>50</td><td>50</td><td>50</td><td>50</td></tr>
<tr valign="bottom"><td><strong>Average Power Rating*, kW:</strong><br> @ 50 MHz<br> @ 108 MHz<br> @ 400 MHz<br> @ 900 MHz</td><td><br>20<br>13.6<br>6.4<br>--</td><td><br>20<br>13.6<br>6.4<br>5</td><td><br>20<br>13.6<br>6.4<br>--</td><td><br>20<br>13.6<br>6.4<br>5</td></tr>
<tr><td><strong>Peak Power Rating*, kW:</strong></td><td>145</td><td>145</td><td>145</td><td>145</td></tr>
<tr valign="bottom"><td><strong>VSWR, Guaranteed Max.:</strong><br> 0-216 MHz<br> 216-400 MHz<br> 400-900 MHz</td><td><br>1.02<br>1.03<br>--</td><td><br>1.02<br>1.03<br>1.06†</td><td><br>1.02<br>1.03<br>--</td><td><br>1.02<br>1.03<br>1.06†</td></tr>
<tr valign="bottom"><td><strong>Isolation, Typical, dB:</strong><br> 0-216 MHz<br> 216-400 MHz<br> 400-900 MHz</td><td><br>60<br>55<br>--</td><td><br>60<br>55<br>40</td><td><br>60<br>55<br>--</td><td><br>60<br>55<br>40</td></tr>
<tr><td><strong>Insertion Loss, dB:</strong></td><td>0.1</td><td>0.1</td><td>0.1</td><td>0.1</td></tr>
<tr valign="bottom"><td><strong>Switching Time, Seconds:</strong><br> Maximum<br> Typical</td><td><br>2<br>1</td><td><br>2<br>1</td><td><br>2<br>1</td><td><br>2<br>1</td></tr>
<tr><td><strong>Pressurization</strong></td><td>No</td><td>No</td><td>No</td><td>No</td></tr>
<tr valign="bottom"><td><strong>Power Source:</strong><br><br></td><td>120 VAC ±10%,<br>50/60 Hz</td><td>120 VAC ±10%,<br>50/60 Hz</td><td>220/240 VAC<br>±5%, 50/60 Hz</td><td>220/240 VAC<br>±5%, 50/60 Hz</td></tr>
<tr valign="bottom"><td><strong>Optional Interface Relay Operation Power, Nominal, Watts:</strong></td><td>1</td><td>1</td><td>1</td><td>1</td></tr>
<tr valign="bottom"><td><strong>Power Drain, Watts (during switching):</strong></td><td>40</td><td>40</td><td>40</td><td>40</td></tr>
<tr><td><strong>Interlock Contact Rating:</strong><br> @ 24 VDC/120 VAC<br><br> @ 240 VAC<br> </td><td><br>7 Amps Res,<br>5 Amps Ind<br>6 Amps Res,<br>4 Amps Ind</td><td><br>7 Amps Res,<br>5 Amps Ind<br>6 Amps Res,<br>4 Amps Ind</td><td><br>7 Amps Res,<br>5 Amps Ind<br>6 Amps Res,<br>4 Amps Ind</td><td><br>7 Amps Res,<br>5 Amps Ind<br>6 Amps Res,<br>4 Amps Ind</td></tr>
<tr valign="bottom"><td><strong>Dimensions:</strong><br>(L x W x D)<br> Inches<br> mm</td><td> <br> <br>8 x 8 x 10<br>200 x 200 x 250</td><td> <br> <br>8 x 8 x 10<br>200 x 200 x 250</td><td> <br> <br>8 x 8 x 10<br>200 x 200 x 250</td><td> <br> <br>8 x 8 x 10<br>200 x 200 x 250</td></tr>
<tr valign="bottom"><td><strong>Weight:</strong><br> Pounds<br> kg</td><td> <br>13<br>6</td><td> <br>13<br>6</td><td> <br>13<br>6</td><td> <br>13<br>6</td></tr>
<tr><td><strong>Order Numbers:</strong></td></tr>
<tr valign="top"><td> Switch with 4 standard<br> 1-5/8" EIA connectors</td><td>961-0020-001</td><td>961-0020-003</td><td>961-0020-002</td><td>961-0020-004</td></tr>
<tr valign="top"><td> Switch with 4 optional<br> 7/8" EIA connectors</td><td>961-0020-005</td><td>961-0020-007</td><td>961-0020-006</td><td>961-0020-008</td></tr>
<tr valign="top"><td> Model 33630A Coaxial<br> Switch Control Panel</td><td>913-0069-001</td><td>913-0069-001</td><td>913-0069-002</td><td>913-0069-002</td></tr>
<tr><td colspan=5><hr width=90%></td></tr>
<tr><td colspan=5><table cellpadding=6 cellspacing=0 width=90%>
<tr><td width=45%>Low Level Interface Relays</td><td align="center" width=20%>12 VDC</td><td align="center" width=20%>24 VDC</td><td align="center" width=20%>48 VDC</td></tr>
<tr><td> Factory Modification Kit</td><td align="center">942-0087-001</td><td align="center">942-0087-002</td><td align="center">942-0087-003</td></tr>
<tr><td> Field Modification Kit</td><td align="center">942-0094-001</td><td align="center">942-0094-002</td><td align="center">942-0094-003</td></tr>
</table></td></tr>
<tr><td colspan=5><hr width=90%></td></tr>
<tr><td colspan=5><table cellpadding=6 width=90%>
<tr valign="top"><td>*</td><td>At unity VSWR and 40º C (104º F) ambient temperature. Average and peak power ratings apply to switches equipped with standard 1-5/8" EIA connectors. For any port equipped with the 7/8" EIA connector, the average power ratings are 6.8 kW at 50 MHz, 4.6 kW at 108 MHz and 2.4 kW at 400 MHz. The peak power rating for any port equipped with the 7/8" EIA connector is 60 kW.</td></tr>
<tr valign="top"><td>†</td><td>Adjusted for a specified 10 MHz band. VSWR may be higher at other frequencies.</td></tr>
</table></td></tr>
</table></td></tr>
</table>
</center>
<hr>
For additional information on any of our products, please contact <a href="mailto:[email protected]">Sales</a> to discuss your particular requirements:<br>
<center><table cellpadding=20>
<tr valign=top>
<td><strong>Delta Electronics, Inc.<br>
5730 General Washington Drive<br>
P. O. Box 11268<br>Alexandria, VA 22312</strong></td>
<td><strong>Phone: (703) 354-3350<br>
U.S. Toll Free: 1-800-8-DELTA-8 (1-800-833-5828)<br>
Fax: (703) 354-0216<br>
<address>www.deltaelectronics.com</address>
Email: <a href="mailto:[email protected]">[email protected]</a></strong></td>
</tr>
</table></center><hr>
<center><table border=2 cellpadding=10 bgcolor=White>
<tr>
<td><strong><a href="../index.html">HOME</a></strong></td>
<td><strong><a href="../amprod.htm">AM/FM/TV Products</a></strong></td>
<td><strong><a href="../hfprod.htm">HF/VHF/UHF Products</a></strong></td>
</tr>
</table>
<font size=1>The Delta Electronics logo is a registered trademark of Delta Electronics, Inc.</center></font>